This section contains information on the practices for preparing occurrence records for entry into the xBio:D database using the Data Entry Assistant (DEA) 2.0. The DEA2 web application requires that occurrence records be present in a properly formatted data entry template (File:Data Entry Template 28-Aug-2014.xls) file according to the Data Transcription Procedures protocol or a properly pre-formatted data entry template File:DEA data entry template-full 28-Aug-2014.xls.

The DEA Processing steps do not need to be followed in the order defined in this document, but all of the parts specified do need to be completed when starting from verbatim label data. If pre-formatted specimen data is used, DEA2 will check to see if the specified values are valid according to xBio:D Controlled Vocabularies.


DEA Preparation

Login

Go to the Data Entry Assistant (DEA) 2.0 web application, click on the login link in the menu on the upper-right hand part of a page, and log in. An xBio:D user account is required to prepare a file within DEA2. If an xBio:D account is needed, go to the DB Manager web application, and sign up for an account.

Login


File Upload

After logging in, the specimen data file, which is an Excel spreadsheet, must be uploaded into DEA2. Go to File -> Load File from the menu to go to the Load File page. Once there, click on the Browse button and select the Excel file to upload. Click the Upload button and the Excel file will be uploaded and standardized in DEA2. Standardization involves created two additional worksheets, "Main" and "Localities", and copying the specimen records from the "Raw_Data" worksheet to the "Main" worksheet, if the file has not already been standardized or pre-formatted. During standardization, DEA2 will verify the consistency of certain fields to make sure that they conform to expected values, i.e., dates are properly formatted, numbers do not contain improper characters, etc. DEA2 will also assure that each cuid is unique within the file and report those that are duplicates before proceeding. The "Main" worksheet will contain the DEA-formatted information necessary for specimen record entry into the xBio:D database. After standardization is completed, the uploaded file is set as the current loaded file and is available to begin DEA Processing.

Upload file

When specimen records are already within the xBio:D database, a list of cuids is displayed so the user may use the list as a reference to verify that the existing records within the database and file are authentic. There records can be downloaded within an Excel spreadsheet by clicking on the Excel logo preceding the list of records.

Records already in DB

Note: File upload and standardization is variable and may take a few minutes to complete depending on the number of records within the Excel file.


Load Existing File

When an Excel file has been uploaded and initially loaded, the file may be reloaded from any computer in which the user has logged into DEA2. By selecting the currently loaded file or the text "no file selected" next to the username in the menu at the top right of a page, a list of the loaded files available to the user as well as some actions that may be performed on the file are presented. Any of the loaded files may be reloaded by clicking on the filename, and the recently loaded file will be displayed within the menu once loaded. Switching to a different file at any time is perfectly appropriate and will not cause any harm.

Loaded files


Search for File or cuid

To see if a file has already been uploaded, search for the file from the search bar near the top of each page within DEA2. The search will find and list the owner of any currently loaded file that contains the search string. By searching for a cuid, the search will report the currently loaded file or files in which the cuid is present.

Search for cuid
Search for file


DEA Processing

Taxonomic Name Checking

Every taxonomic name that is specified within a taxonomic column, viz., order, superfamily, family, subfamily, genus, species, and subspecies, must be present within the xBio:D database in order to enter a specimen record. Checking that these taxa are in the database is accomplished by clicking on Batch -> Check Taxa within the DEA2 menu at the top left of a page, then clicking the YES button next to Begin processing? on the Check Taxa page. DEA2 will take the taxa from the "Raw Data" worksheet, verify that they are in the database, then copy these values to their corresponding column in the "Main" worksheet. A taxonomic identification for a specimen record that is of a higher rank than family, i.e., not identified to family or more specific, will have the xBio:D database ID for that taxon placed within the family column for the specimen record. This translation will occur automatically "behind-the-scenes" during taxon checking within DEA2.

Begin checking taxa

If a taxonomic name is not in the database, a form populated with the taxa for the offending specimen record will be displayed and the name that is not present will be highlighted. The form will allow the user to select the correct taxonomic name for a rank from an interactive search box, or ignore the current taxa and move on to the next group of names. The taxonomic name search box will display a list of matches from the current text string and prepend invalid taxa with an asterisk (*). If a taxonomic name has more than one taxon associated with it, i.e., homonymy, then the user can select the correct taxon with author combination to replace the homonym with its xBio:D database ID. Once the taxonomic changes have been specified, click the Edit button to reflect the modifications into DEA2 or press the Ignore button to ignore the taxa until later during specimen record entry. Batch checking of the taxa will resume once one of the two button are clicked.

Choose desired homonym
Edit and resume processing

Under Page Options on the left menu, users can select Review set taxa to review which specimens records have been processed and the current taxonomic names for the records.

Review checked taxa

Users with authority over a taxonomy can enter new taxonomic names within the DB Manager web application.


Setting Determiner

Individuals within the xBio:D database are their own controlled vocabulary and are not discriminated based on whether the individual is a collector, author, or determiner. Because of this, all individuals or a collective group of individuals, known as a party, must be present within the xBio:D database. To verify that the determiners are present, go to Set -> Set Determiner from the DEA menu, which will load the Set Determiners page. The initial determiner string is the value for the record that was copied from the "Raw Data" worksheet, and this determiner name is specified within the Determiner search box. Place your cursor within the search box to interactively search for the determiner to see if his/her name is already in the xBio:D database. A wildcard (%) is automatically appended at the end of the search text may to help find abbreviated names, e.g., Mues. -> Mues -> Muesebeck, C. F. W.. Clicking on a name will copy the individual's name into Determiner box. Individual names will always be formatted with the last name (family name) first, then the person's initials. The given name parts are optional but will unambiguously identify a person when a separate individual shares the same last name and initials.

Set the determiner

When an identification is made by more than one person, a party will need to be set as the determiner. Within the Determiner search box, search for one of the determiners, and from the list of people and parties, select the correct party. Once the party is selected, the xBio:D party ID will replace the search box text. An xBio:D person ID will also replace individual names that cannot be unambiguously specified. New parties can be formed within the DB Manager web application.

Search for and select a party
Determiner replaced by xBio:D party ID

After the determiner has been confirmed and any name ambiguity removed, press the Set Determiner button to assign the search box text as the determiner for all of the records in which the original determiner value was present. Using the above example, Muesebeck, C. F. W. would be set as the determiner for all determiner values that matched Mues.. If a determiner is not specified, press the No Determiner Specified button to skip the current record and all matching records until the next distinct determiner value is found.

Under Page Options on the left menu, users can select Review set determiners to review which specimens records have been processed and the current determiner for the records. If a determiner was incorrectly set, press the Remove button next to the record which contains the improper determiner string to remove the action and allow the user to process the record again. DEA2 will remove the set determiner action for all of the records in which the new_comments column matches the selected record. The previously set, not original, determiner value will remain in the "Main" worksheet to allow the user to easily reset correct determiners that had their action inadvertently removed. Although this seems a bit counter-intuitive, through user feedback on real-world examples, the current behavior to remove actions for determiners is the most effective.

Review set determiners and remove action


Setting Dates

Collecting dates within the xBio:D database come in two different varieties: specific dates and periods. Specific dates are an exact day or a range of days when the specimen was collected, while a period is a generalized, non-specific time period in which a specimen was collected. To begin setting collecting dates, go to Set -> Set Dates from within the DEA2 menu to load the Set Dates page. DEA2 will attempt to interpret the specimen date from the specimen label data in the new_comments column. Since label data is very heterogeneous, the date interpreter often makes mistakes or does not recognize a date. Be very attentive to which values are placed within the date boxes! If a specific date (a precise day or range) must be added, e.g., 12-vii-2003, 1-12.xi.1988, etc., use the date format DD-MON-YEAR where DD is the two-digit day, e.g., 10, 06, 31, MON is the three-character month, e.g., JAN, MAY, DEC, and YYYY is the four-digit year, e.g. 2007, 1932, 1896. If a non-specific date, e.g., Dec. ’74, X-XII-1964, etc., or an ambiguously defined date, e.g., 1-2-1934, 12/11/45, etc., the recognizable date elements need to be placed in the Non-specific Period box that best matches a specific date format with a range of dates separated by a dash with spaces, e.g., DEC-1974, OCT-1964 - DEC-1964, Summer 1969, etc. The 'Non-specific Period' box searches the xBio:D database for matching periods, but a period does not already need to be present.

Set date (specific)
Set date (non-specific / period)


After the date has been evaluated, press the Set Date button to assign the specified date to all of the records in which the new_comments column matches the current record. If a date is not specified, press the No Date Specified button to skip the current record and all matching records until the next distinct specimen record is found. If the new_comments match a specimen record that had already been entered into the xBio:D database, DEA2 will automatically assign that collecting date to the matching record.

Under Page Options on the left menu, users can select Review set dates to review which specimens records have been processed and the current collecting date for the records. If a date was incorrectly set, press the Remove button next to the record which contains the improper date to remove the action and allow the user to process the record again. DEA2 will remove the set date action for all of the records in which the new_comments column matches the selected record.


Setting Collecting Methods

Collecting techniques or methods define the manner in which the specimen was collected, and like many other elements, collecting methods within xBio:D are a controlled vocabulary. Begin by going to Set -> Set Collecting Methods within the DEA2 menu to load the Set Collecting Methods page. Often shorthand codes are used to specify the collecting method for a specimen, and a short list of the most commonly used collecting methods is listed below.

Collecting Methods List
MT or mal.trap malaise trap
YPT, yellow pan, or Möricke trap yellow pan trap
FIT or flight trap flight intercept trap
sw. or sweep. sweeping
PT or pan pan trap
s.s. screen sweeping
MT/YPT malaise trap/yellow pan trap

Some collecting methods are used in tandem with other methods or samples from multiple collecting methods are mixed together, so care must be taken in interpreting the correct collecting method. Existing collecting methods can be found by typing a part of the method within the Collecting Method search box, which will list all of the matching methods within the xBio:D database. A list of the most recently set collecting methods are shown within the Recent list at the right of the Collecting Method search box. Clicking on a recent collecting method will replace the search box contents with the selected collecting method.

Set collecting method

After the collecting method has been determined, press the Set Collecting Method button to assign the collecting method to all of the records in which the new_comments column matches the current record. If a collecting method is not specified, press the No Collecting Method Specified button to skip the current record and all matching records until the next distinct specimen record is found. If the new_comments match a specimen record that had already been entered into the xBio:D database, DEA2 will automatically assign that collecting method to the matching record.

Under Page Options on the left menu, users can select Review set collecting methods to review which specimens records have been processed and the current collecting collecting method for the records. If a collecting method was incorrectly set, press the Remove button next to the record which contains the improper method to remove the action and allow the user to process the record again. DEA2 will remove the set collecting method action for all of the records in which the new_comments column matches the selected record.


Setting Collectors

As with determiners, each collector of a specimen is an individuals within the xBio:D database are managed within a controlled vocabulary. Begin setting the collectors by going to Set -> Set Collectors within the DEA2 menu to load the Set Collectors pages. Collectors unlike determiners, however, cannot be set as a party and a maximum of three collectors are enforced for a record, so when a specimen record has more than three collectors, the third collector should be set to et al.. Since a record of all of the collectors is kept within the verbatim label contents in the new_comments column, no information should be lost. Party implementation for collectors may be supported in the future based on demand. Search for a collector in the corresponding Collector search box, which are xBio:D database connected boxes, based on the collector's position within the search string. Since aliases are managed within the xBio:D database, the collector chosen within the search box should match the name of the collector on the label. Please refer to Setting Determiner for search strategies and the required format of names of individuals.

Set collectors
Set collectors (more than 3)

A list of the most recently set group of collectors are shown within the Recent list at the right of the Collector search boxes. Clicking on a recent group of collectors will replace the search box contents with the selected group. To clear all of the values within the Collector search boxes, click clear next to the title of the Recent list. New collectors can be added from within the DB Manager web application.

After the collectors have been set, press the Set Collectors button to assign the group of collectors to all of the records in which the new_comments column matches the current record. If a collector is not specified, press the No Collectors Specified button to skip the current record and all matching records until the next distinct specimen record is found. If the new_comments match a specimen record that had already been entered into the xBio:D database, DEA2 will automatically assign that group of collectors to the matching record.

Under Page Options on the left menu, users can select Review set collectors to review which specimens records have been processed and the current group of collectors for the records. If a group of collectors was incorrectly set, press the Remove button next to the record which contains the improper group to remove the action and allow the user to process the record again. DEA2 will remove the set collectors action for all of the records in which the new_comments column matches the selected record.


Setting Localities

A locality name in xBio:D is a string that uniquely defines a collecting locality that usually will contain all of the locality information present within the specimen labels. Since a specimen collected within a house and one collected across the road from the same house may represent vastly different microclimates, for example, specimen records should not contain the same locality name out of convenience. Processing localities requires the greatest amount of attention amongst any of the preparatory steps within DEA2, so understanding the locality name creation conventions is a requirement. Begin by going to Set -> Set Localities from the DEA2 menu to go to the Set Localities page. Search for a locality name in the database that matches all of the locality information within the new_comments field. Since a number of locality names may have small differences, pay close attention to the specific details within a locality name, e.g., nr. Igarapé Tarumã, Manaus, AM, Brazil, nr. Igarapé Tarumã-Mirim, igapó, Manaus, AM, Brazil and Igarapé Tarumã-Mirim, igapó (black water inundation forest), 20km NW Manaus, AM, Brazil. Wildcards (%) should be used when searching for a locality name to match any character before or after a search string, such that the search %Manaus%Brazil would match the three localities from the previous example and many more. Press the Search button to display all of the localities in the xBio:D database that match the search string.

Set matching locality

Depending on the locality name convention, a locality name should include any field codes, e.g., T45, CAR01-345, MA-02A-45, etc.; generalized locality terms, e.g., across the road, downstream, well nr. road, etc.; and habitat information, e.g., nothofagus forest, rainforest, sand dunes, etc. Specific biological associations related to potential host/parasite animals, e.g., feeding on cow, emerged from Nezara sp., etc., and plant hosts, e.g., on flower of lily, from Zea mays, etc., are omitted from the locality name but included within a separate biological association section within the "Main" worksheet. Associations will need to be processed outside of DEA2 for the time being.

New locality names are created using the following format:


[Town / National Park / Reserve], [coordinates on label], [elevation], [field code], [habitat], [generalized locality term], [further locality information], [geopolitical hierarchy]


Examples:

Andohahela National Park, 24°49.85'S 46°32.17'E, 80m, MA-02-21-29, dry spiny forest, parcel III, Ihazofotsy, Toliara Auto. Prov., Madagascar
Rancho Nuevo, nr. beach, Barra Coma, Aldama Mpio., TAMPS, Mexico
Doolittle Ranch, 9800ft, Mt. Evans, Clear Creek Co., CO

If a locality name match is found, click on the locality from the list of matches to set the locality name for all of the records in which the new_comments column matches the current record. If a locality name match is not found, press the Skip Locality button to skip the current record and all matching records until the next distinct specimen record is found. DEA2 handles a locality that is skipped by placing the cuid and new_comments fields for the specimen record into the "Localities" worksheet. The record within the "Localities" worksheet must be georeferenced outside of DEA2 then later reloaded and entered. If the new_comments match a specimen record that had already been entered into the xBio:D database, DEA2 will automatically assign that locality name to the matching record.

Skip locality

Under Page Options on the left menu, users can select Review set localities to review which specimens records have been processed and the localities for the records. If a locality was incorrectly set, press the Remove button next to the record which contains the improper locality to remove the action and allow the user to process the record again. DEA2 will remove the set localities action and remove the record within the "Localities" worksheet for all of the records in which the new_comments column matches the selected record.


Changes from DEA to DEA2

  • All actions performed within DEA2 are recorded, which requires an xBio:D user account. This allows a user to process a file seamlessly between multiple computers.
  • DEA2 is at least 4 times faster than the original DEA, and also contains more consistency checks and better error handling.
  • Verbatim label fields do not need to be merged with the comments field prior to entry into DEA2 unlike the original DEA.
  • DEA2 can handle many more specimen records in a single file. Whereas DEA maxed out at ~500 specimens, DEA2 has easily processed files with as many as 8000 specimens.
  • DEA2 performs some consistency checks upon upload to verify that cuids are unique within the file, dates are properly formatted, required fields are present, etc. After the consistency check, DEA2 will report any specimens within the file that are already located within the xBio:D database.